A lithium iron phosphate (LFP) battery system just lately exploded in a house in central Germany, stopping police and insurance coverage investigators from coming into because of the excessive danger of collapse. The explosion might have been preceded by off-gassing, however it stays unclear whether or not an exterior ignition supply was the trigger. Some scientists say thermal runaway might have triggered the blast.
Round three weeks in the past, the explosion of a 30 kWh battery storage system induced a stir in Lauterbach, within the central German state of Hesse. The system proprietor is an electronics technician specializing in power and constructing providers, with 20 years {of professional} expertise.
His house was destroyed within the explosion and it has not been liveable since. It’s now in acute hazard of collapsing, which is why police and insurance coverage investigators don’t dare to enter. This makes it not possible to find out the reason for the explosion with 100% certainty. The home will quickly be demolished.
The house owner advised pv journal that the battery power storage system consisted of three battery packs from Shenzhen Basen Expertise. He purchased two in June 2022 and an extra one in June 2023 by way of the Alibaba platform. They’re the “BR-48200B” and “MY-381” fashions, every with 10 kWh of capability based mostly on LFP know-how housed in a 19-inch cupboard.
The battery system was coupled with a 15.47 kW photovoltaic system, which the house owner was about to increase to 19.565 kW, and two completely different inverters: Victron’s Multiplus II 5000 and Solax X1 4.2. The reason for the explosion has but to be clarified, and there have been no electrical clues, in accordance with the house owner. Proper earlier than the accident, the battery’s state of cost (SOC) was 90.2% and the voltage stood at 52.41 V.
After the explosion, the basement – which housed each the boiler and the battery system – was crammed with white smoke. Nonetheless, there have been “hardly any indicators of fireplace” close to the battery storage unit, in accordance with the house owner. “The inverters on the opposite aspect of the room appear to be new,” he stated.
Lengthy after the incident, the house owner observed an odor that he described because the scent of lithium. He’s now making an attempt to find out whether or not it’s is smart to hold out security checks outdoor for outdoor-use gadgets, because the smoke can evaporate and be neglected. Now, the query is which gasoline induced the explosion, whether or not it originated inside or outdoors the battery, and the way it occurred.
pv journal contacted two scientists, however the had been unable to touch upon the precise incident because of the ongoing investigation. Egbert Figgemeier, chair of getting old processes and battery lifetime prediction at RWTH Aachen, stated that it’s conceivable that the electrolyte within the cells broke down and an inside brief circuit ignited the gases.
“An exterior ignition supply just isn’t needed,” stated Figgemeier.
He described the white smoke because the decomposition merchandise of the electrolyte, which might additionally comprise harmful gases. Soot formation just isn’t essentially to be anticipated, as many elements of the cells may burn with out leaving any residue at excessive temperatures. So-called thermal runaway may have preceded the explosion and should have been the set off.
Axel Durdel, a researcher on the Technical College of Munich, advised pv journal that in a “worst-case situation,” an LFP battery may leak hydrogen, carbon dioxide, carbon monoxide, ethene, methane and different gases. There was a whole lot of dialogue in regards to the attainable formation of hydrogen with a subsequent explosion. In precept, that is attainable, however whether or not the circumstances for spontaneous combustion have been reached can’t be estimated, in accordance with Durdel.
He stated it isn’t recognized that batteries may trigger such an explosion and not using a thermal response. Within the case of thermal response, the interior stress may enhance resulting from undesirable aspect reactions, resulting in an explosion and the discharge of scorching gases.
“Within the case of batteries with a decrease power density or a low state of cost, it’s solely attainable that the gasoline doesn’t ignite instantly when it exits the battery, however that the ignition happens by exterior ignition sources,” stated Durdel.
In that case, there ought to be traces on the battery. Nonetheless, this may not be verified as a result of nobody is allowed to enter the house because of the danger of collapse.
The storage proprietor has famous the issue of finishing up security checks with lithium-ion storage gadgets outdoor. Figgemeier confirmed that such experiements are carried out in semi-open bunkers, relatively than in closed rooms.
Durdel stated that the standard-compliant security checks for the lithium-ion cells are carried out nearly completely in take a look at rooms with acceptable filter programs. In precept, it’s conceivable that gases may accumulate within the basement with out an acceptable exhaust system. Nonetheless, the scientist from the Technical College of Munich couldn’t say whether or not this was enough for self-ignition.
Battery storage is usually protected when professionally put in and authorized, with compatibility between programs ensured by testing and approval by inverter and battery producers.
For built-in programs, that is finished by the system integrator. The security of those programs is clear within the low variety of accidents reported amongst greater than 1 million house battery storage installations in Germany. Monitoring programs, frequent amongst established producers, additional help within the early detection of vital circumstances.
This content material is protected by copyright and will not be reused. If you wish to cooperate with us and wish to reuse a few of our content material, please contact: editors@pv-magazine.com.